Super Insulation Materials

 

Cryogenic Multilayer ( Super Insulation Materials )

 

Applications

 

Insulation for Cryogenic Liquid Gas which are named LNG, LOX, LIN, LAr, L-Hydrogen, LCO2, L-Helium.

 

Cryogenic storage tanks and semi-trailers.

LNG tank, semi-trailers and containers.

LNG vessel for automobile.

Cryogenic Pipeline.

 

Super Insulation Material made from foil and superfine glass fiber. It can be pre-composited to be multilayer as per request in order to increase the wrapping efficiency. It is suitable for applications with the temperatures range from -260 °C to 500 ° C  

 

Advantages

 

Low thermal conductivity ( see below conductivity performance chart )

Thin, Light and highly uniform

Flame resistant

Non-outgassing, inorganic won’t impair the integrity of sealed vacuum containers

Enable fast pump-down time

 

 

Parameters

 

Insulation Material Thickness : 0.06 +-0.01mm.

Aluminum Foil Thickness : 0.0065mm.

Insulation Material Weight : 13.6 +-1g/m2

Aluminum Foil Weight : 17+-1g/m2

Insulation Material Tensile Strength : buyukesit 0.03KN/m.

Aluminum Foil Tensile Strength :buyukesit 0.4KN/m.

Insulation Material Moisture Content : kucukesit 0.5%

Insulation Material Organic Content : kucuk 0.5%

Ensemble Thermal Conductivity : kucuk 1.5x10uzeri-4   w/m.k

Cryogenic Out-gassing(Static State 1h) : kucuk1.0x10uzeri-8 Pa.m3/s.g

Application Temperatures Ranging : -260° C – 500° C